KleenFlo™ Series Pulse-Jet Cartridge Dust Collector Principles
of Operation Previous
Page
Normal Operation
During normal operation, dirty air enters the top of the KleenFlo collector and moves downward through the filter cartridges, leaving dust on the outer surface of the cartridge element. Clean air exits through the center of the cartridge to the plenum and exits the unit. Pulse-jet technology, controlled by a programmable timer, releases compressed air down the cartridge to release dirt which falls off into the hopper below for removal.